Pitt-Char XP provides up to 2 hours protection against jet fire impingement.

Pitt-Char Coatings have been fire tested at more than 12 fire testing facilities around the world. Our products have received approvals and certificates from Underwriters' Laboratories Inc. (USA and Canada), Det Norske Veritas (Norway), Lloyd's Registry of Shipping (UK), GASAFE (France), and from several customers based on their own in-house fire testing. Testing has covered a range of heat fluxes including jet fire impingement testing on various steel section geometries and sizes. A sampling of fire test results are listed in the following table. For additional test information, including actual explosion testing up to 1.8 bar overpressures, consult your local Pitt-Char XP Coating Technical Sales Representative.

PRODUCT FIRE TEST RESULTS

TEST DESIGN

TEST METHOD

FIRE RATING

Structural Steel - Range of Hp/A Values for I Sections and RH Sections

NordTest Method NT Fire 021

1 to 4 hours Hp/A from 25 to 300 Failure Temperatures 200°C to 700°C

Underdecks
H60
H120

IMO RES using exposure model described in ISO 834


11.0 mm (0.43")
15.0 mm (0.59")

Bulkheads
H60
H120
HO-400°C

A-60

IMO RES using exposure model described in ISO 834


IMO RES A 0.517 (13)


10.0 mm (0.39")
14.0 mm (0.55")
7.0 mm (0.28")

8.0 mm (0.31")

Surface Flammability

ASTM E-84

Flame Spread=15
Smoke Development=70-110

Column Test UL
Design No. X-623

UL 263 "Fire Tests of Building Construction and Materials"

Fire Ratings from 1 to 3 hours
Covering Steel Sizes:
W/D: .84 to 3.55
Hp/A: 160 to 38

Beam Test UL
Design No. N-612

UL 263 "Fire Tests of building Construction and Materials"

Restrained Beam Rating - 4 hrs.
Unrestrained Beam Rating - 3 hrs.
Covering Steel Sizes:
W/D: .68 to 1.75
Hp/A: 197 to 77

Column Test UL
Design No. XR-612

UL 1709 "Fire Tests of Structural Steel Protected for Resistance to Rapid Temperature Rise Fires"

1 hr.: 0.28"(7.1 mm)
1 1/2 hr.: 0.40"(10.2 mm)
2 hr.: 0.52"(13.2 mm)
2 1/2 hr.: 0.63"(16.0 mm)
3 hr.: 0.75"(19.1 mm)

Jet Fire Test

OTI 95-634 "Jet Fire Resistance Test of Passive Fire Protection Materials"

Protection up to 2 hrs.

LPG/LNG Storage Tanks

US - DOT
France - GASAFE

Protection up to 4 hrs.